| Channels | 5 |
| Class | D-class |
| Power supply voltage / fuse | 22 ÷ 33 VDC / 2 x 15 A |
| Idling current | 1 A |
| Idling current when off | 0.04 mA |
| Consumption @ 14.4 VDC, 2Ω, Max Musical Power | 15 A |
| Remote IN | 7 ÷ 33 VDC - 1 mA |
| ART - Automatic Remote Turn on/off from OUTPUT BTL speakers (Selectable) | Automatic Remote Turn-OniOff with Speaker-ln |
| Distortion - THD @ 100 Hz, 4Ω, 70% Rated Power | 0.02% |
| Bandwidth A |
(-3 dB) A, B Ch: 10 ÷ 50k Hz -3 dB) C (sub) Ch: 10 ÷ 500 Hz |
| S/N ratio A | (A weighed @1 V): 100 dB |
| Damping factor A |
(100 Hz @ 4 Ω): 100 (100Hz @ 4Ω) SUB: 250 |
| Input sensitivity Pre-In | 0.2 ÷ 5 VRMS |
| Input sensitivity Speaker-In | 0.8 ÷ 20 VRMS |
| Total Power RMS | 640 W |
| Minimum load impedance |
@5Ch:2 Ω @3Ch:4 Ω + 4 Ω + 2 Ω |
| Output Power (RMS) @14.4 VDC, 1% THD |
5 Ch: 55 W x 4 + 160 W x 1 (4 Ω) 5 Ch: 90 W x 4 + 280 W x 1 (2 Ω) 3 Ch: 180 W x 2 (4 Ω) + 160 W x 1 (4 Ω) 3 Ch: 180 W x 2 (4 Ω) + 280 W x 1 (2 Ω) |
| Output Power (RMS) @14.4 VDC, 10% THD |
5Ch 55 W x 4+160 W x 1 (4Ω) 5Ch 90 W x 4+ 280 W x 1 (2 Ω) 3Ch 180 W x 2 (4 Ω) +160 W x 1 (4 Ω) 3Ch 180 W x 2 (4 Ω)+280 W x 1 (2 Ω) |
| Adjustable Crossover | Yes |
| Input Type | PRE IN / SPEAKER IN |
| Filter Pass A | FRONT Ch. filters - FULL: Yes Hi-Pass: 50 ÷ 5 kHz @ 12 dB/Oct |
| Filter Pass B | REAR Ch. filters - FULL: Yes Hi-Pass: 50 ÷ 5 kHz @ 12 dB/Oct |
| Filter Pass C | REAR Ch. filters - Band-Pass: 50 ÷ 500 Hz (Hi) @ 12 dB/Oct Band-Pass: 50 ÷ 5 kHz (Lo) @ 12 dB/Oct |
| Sub CH | SUB Ch. filter LO-PASS: 50 ÷ 500 Hz @ 24 dB/Oct. |
| Phase | Not available |
| Bass Boost | (0 ÷12) dB |
| Subsonic | 25 Hz @ 24 dB/Oct |
| Remote Sub Volume | (-50 ÷ 6) dB |
| Weight | 3 kg |
Electronics components corrosion caused by exposure in wet environments is totally neutralized by the use of dedicated marinegrade (epoxy coated) PCB boards.
To satisfy the standards required by ASTM-B117, Hertz Marine products are tested with massive salt fog spray to ensure a complete resistance to corrosion, typical of this atmospheric agent.
Power supply featuring multiple winding transformer, Low-ESR 105°C capacitors, D-Class 2 Ω stable output stage.
This Hertz Marine amplifier is IPX2 certified when installed vertically with connections facing downward.